Incident

Suspected ransomware attack on Guadeloupe's university hospital: records unreachable, staff on pen and paper, radiotherapy suspended

On the evening of Saturday 21 November 2026 a cyberattack disrupted IT and telephone systems at the University Hospital of Guadeloupe, which triggered its Plan Blanc emergency plan the next day and postponed non-urgent surgery, consultations and scheduled imaging through 27 November. France's cybersecurity agency ANSSI said the incident appeared to involve ransomware, and the Paris prosecutor opened a criminal investigation.

Fact-checked 26 November 2026

TierElectronic medical records, imaging, lab and printing systems were unavailable and staff worked with pen and paper and couriers. Phones were also reported out of service, but later reports describe telephony disrupted mainly at one site and the 15 emergency line working, so loss of both data and voice is not clearly documented. How tiers are assigned.

What happened

According to RCI, the hospital's director, Eric Guyader, said on 22 November that IT and telephony had been impeded by a cyberattack the previous evening. He said systems would not be back within the next two or three days and that it would be hard to restart both the software and the databases. RCI reported that day that the telephone, imaging, non-urgent biology, printers and software were out of service, and that all three sites (Pointe-à-Pitre, Perrin and Palais Royal in Les Abymes) were affected. It said the laboratory and radiology were heavily affected and that there was a risk of errors in transmitting test results. Management decided on Sunday 22 November to trigger the Plan Blanc. RCI reported that IT and telephone systems were disrupted mainly at the Chauvel site, and that the three sites were affected to differing degrees. Part of the scheduled surgery, consultations and imaging was postponed through Friday 27 November, while urgent and priority care continued. RCI also reported that the emergency number 15 was working normally. The Record reported that the outages turned out to be a cyberattack that encrypted the hospital's databases, and that as of Tuesday 24 November staff still could not access patients' electronic medical records. The director told local media, as quoted by The Record: "We're back to pen and paper, relying on couriers who travel from one department to another." Citing the hospital's website, The Record reported that radiation therapy was temporarily suspended over safety concerns and that chemotherapy sessions scheduled for Monday were cancelled. Emergency services, dialysis and urgent cardiac procedures remained available. According to The Record, ANSSI said on Tuesday that the incident appeared to involve ransomware, and investigators were examining whether the attackers entered through an unnamed IT supplier reportedly compromised several months earlier. The Record also reported that management had received no ransom demand and ruled out paying one, and that it was unclear whether personal or medical data had been stolen. RCI reported that the cybercrime section of the Paris prosecutor's office opened an investigation on 23 November and assigned it to the Office anti-cybercriminalité. Health minister Stéphanie Rist said, as quoted by The Record: "The cybersecurity of our hospitals is also the safety of our patients."[1,2,3,4]

Documented harm

none documented

What it teaches

  • When an outage takes out phones as well as clinical software, departments need a non-electronic way to pass results and orders, such as couriers, planned in advance.
  • Lab and imaging results passed by hand during downtime carry a risk of transcription and routing errors, so downtime procedures should include checks on result transmission.
  • Treatments such as radiotherapy may have to stop entirely when their supporting systems are lost, so continuity plans should set out how such patients are triaged and rescheduled.
  • Access through IT suppliers is a possible route into hospital networks, so supplier connections belong in the scope of security monitoring and incident plans.

Sources

  1. Suspected ransomware attack disrupts cancer treatments, surgeries at Guadeloupe hospital. The Record from Recorded Future News, 25 November 2026. Secondary Journalism · link checked 2026-11-26
  2. Le CHU de Guadeloupe victime d'une cyberattaque, une cellule de crise déclenchée. RCI, 22 November 2026. Supporting Journalism · link checked 2026-11-26
  3. Cyberattaque au CHU : un plan blanc annoncé par la direction. RCI, 23 November 2026. Supporting Journalism · link checked 2026-11-26
  4. Cyberattaque au CHU de Guadeloupe : le parquet de Paris ouvre une enquête. RCI, 23 November 2026. Supporting Journalism · link checked 2026-11-26

IT outage takes down the whole IT system at Luxembourg's Centre Hospitalier du Nord; records go to paper and ambulances are redirected

On 23 November 2026 an IT outage affected the entire IT system of the Centre Hospitalier du Nord in Ettelbruck, according to the hospital. Inpatient records were made available on paper, outpatient appointments were cancelled and ambulances were directed to other hospitals until the system was restored shortly after 18:00. The hospital said the cause was purely technical and not a cyberattack.

Network failure at UZ Brussel takes down its shared patient record at partner hospitals; care moves to paper and ambulances are diverted for about a day

A network problem at UZ Brussel affected its IT infrastructure and telephony, according to the hospital. For about 24 hours, planned care was postponed, ambulances were diverted and staff worked on paper. Partner hospitals that use the same UZ Brussel-developed electronic patient record also lost online access to patient files.

PathConnectivity & data → Human handoff

Server outage at Monadnock Community Hospital: ambulance diversion, cancelled elective surgery, lab and radiology, and a week on downtime procedures

An outage that began on 9 November 2026 and that the hospital later called a server outage put Monadnock Community Hospital's emergency department on ambulance diversion. It also led the hospital to cancel elective surgery and outpatient laboratory and radiology appointments. The hospital said it was working under downtime procedures. As of 15 November its phones were restored, other systems were still down, and on 16 November it confirmed that a cyber incident caused the outage (DysruptionHub).

PathConnectivity & data → Human handoff

Quest Diagnostics shuts down its Quanum LSM lab ordering and results system after unauthorized access; clients told to use paper requisitions

After a cyber intrusion, Quest Diagnostics shut down Quanum LSM, the web system some clients use to order lab tests and receive results, and paused two other systems as a precaution. Clients were told to use paper requisitions or another Quest platform. Quest says its ability to serve patients was not materially disrupted.

PathConnectivity & data → Human handoff

Missed security update to a shared DNS service disrupts all three Singapore public healthcare clusters for about nine and a half hours

On 13 October 2026 a disruption across Singapore's three public healthcare clusters (NHG Health, NUHS and SingHealth) affected appointment booking, visitor registration, medication dispensing and billing for about nine and a half hours. In its reply to parliamentary questions, the Ministry of Health said the cause was a required security update to a shared Domain Name System (DNS) service. Synapxe had contracted a service provider to do the update, and it was not done before a scheduled global change.

PathConnectivity & data → Human handoff

Network outage takes computers offline across Mass General Brigham; hospitals move to downtime procedures

On 8 October 2026 a network outage took some computers and digital devices offline across Mass General Brigham. Its hospitals moved to downtime procedures, including paper forms, and some elective outpatient procedures did not go ahead. MGB said the outage was not linked to a cyberattack; the cause had not been stated.

All incidents · Connectivity & data · Human handoff

Information only, not advice. FailSystems is an aggregation and synthesis of published sources. It is not consulting, engineering, legal, regulatory or medical advice, and using it creates no professional relationship. Health systems are complex and no approach fits every organisation: anything you adopt is your own decision, at your own risk, and should be checked against the current official sources and by qualified people who know your setting. Full disclaimer.

Dealing with an incident right now? This site is a reference, not an incident-response service. Activate your organisation's emergency operations plan and incident command, and: