Ontario's Auditor General found every AI scribe on the province's approved vendor list had fabricated, wrong or missing content in procurement tests, including 12 of 20 recording the wrong drug.[26,27]
A pharmacy chain's AI voice and text assistant for refills mispronounced medications, ordered wrong dosages and duplicate refills, and gave callers no keypad alternative; after hundreds of complaints the chain pulled it back.[28,29]
After AI polyp detection was introduced, the adenoma detection rate of standard non-AI colonoscopy fell from 28.4% to 22.4%.[11]
An automated sepsis alert triggered a protocol for large-volume IV fluids in a dialysis patient; the nurse objected, was told to follow the protocol, and a physician intervened.[30,31]
A Class I software correction found that backlogged EHR-to-pump automated programming requests could load stale rate, dose or volume parameters.[32,33]
Researchers and an AP investigation found OpenAI's Whisper speech-to-text model inserting fabricated sentences, and a Whisper-based clinical scribe used by over 30,000 clinicians erased the source audio, removing the way to check.[34,35]
A faulty Rapid Response Content update to CrowdStrike's Falcon sensor crashed about 8.5 million Windows devices worldwide. Outside-in measurement found disrupted services at 759 of 2,232 US hospitals studied.[36,37,38,39,40,41,42]
PathDevices → Connectivity & data → Human handoff
Ransomware hit Synnovis, the pathology provider for several south-east London NHS trusts and GP practices. Blood testing and matching collapsed, more than 11,000 appointments and procedures were postponed, O-type blood ran short nationally, and one death was later partly attributed to a delayed result.[43,44,45,46,47,48,49,50]
PathConnectivity & data → Human handoff
A ransomware attack took Ascension's electronic records offline for about five weeks. Clinicians told KFF Health News of medication errors and delayed lab results, and one said he had no training for the attack; Ascension said its care teams were trained for such disruptions.[24,51]
Attackers used stolen credentials on a Change Healthcare Citrix remote-access portal that had no multi-factor authentication, then deployed ransomware nine days later. Disconnecting the clearinghouse stalled pharmacy claims, medical claims and payments across the US.[52,53,54,55,56]
PathConnectivity & data → Human handoff
A class action alleges UnitedHealth used naviHealth's nH Predict model to cut off post-acute care; a Senate investigation found UnitedHealthcare's post-acute denial rate nearly tripled while it automated prior authorization.[57,58,59,60]
In a controlled experiment, 27 radiologists' accuracy on mammograms fell sharply when a purported AI suggested an incorrect BI-RADS category.[3]
An independent validation of Epic's proprietary sepsis score found it far less accurate than the vendor reported: it missed 67% of sepsis cases while alerting on 18% of all hospitalizations.[20,61]
A month-long ransomware attack on a health system with about 25% of regional inpatient discharges drove patients and ambulances to two unaffected academic EDs, raising their census, waits and stroke activations.[62,63]
PathConnectivity & data → Human handoff
Freezing weather knocked out generation and forced the largest controlled load shed in US history. Power loss spread to water systems and hospitals, and to patients at home on powered medical equipment.[64,65,66,67,68,69]
PathPower → Devices → Human handoff
After go-live, the new EHR routed more than 11,000 clinical orders to a hidden queue instead of the intended service, without telling the ordering clinician; VHA identified 149 adverse events.[70]
April 2020University of Michigan Hospital, Ann Arbor, MI, USA; alert surge measured across 24 US hospitalsFell to tier 1: assisted operationModels & agents Human handoff
Weeks after its first COVID-19 admissions, the University of Michigan paused Epic sepsis alerts because dataset shift produced spurious alerting; its clinical AI committee decommissioned the model.[71,72]
18 March 2018Tempe, Arizona, USANon-clinical analogueHuman handoff
Non-clinical analogue. The human operator meant to back up an automated driving system was looking at her phone; the NTSB cited automation complacency.[10]
A self-spreading ransomware worm infected 34 English trusts and 603 primary-care and other NHS organisations, and at least 46 more trusts were disrupted. Thousands of appointments were cancelled and five hospitals diverted ambulances.[73,74,75]
PathConnectivity & data → Devices → Human handoff
Ransomware made the EHR inaccessible; the hospital moved to paper within an hour and restored computers after 36 hours.[63,76,77]
Storm surge flooded basements holding fuel tanks and pumps at two Manhattan hospitals whose generators sat on upper floors. Both hospitals evacuated.[78,79,80]
A patient on a cardiac monitor died after the monitor's crisis alarm had been left off; lower-level alarms sounded at the nurses' station but went unheeded.[81,82]
A 60-year-old ICU patient's monitor alarmed for rising heart rate and falling oxygen saturation; staff responded only after about an hour, when he had stopped breathing.[12]
1 June 2009Atlantic Ocean, Rio de Janeiro-Paris flightNon-clinical analogueHuman handoff
Non-clinical analogue. Iced pitot probes caused inconsistent airspeeds, the autopilot disconnected, and the crew did not recognise or recover from a stall.[9,83]
After city power failed, Memorial ran on generators that failed as floodwater rose. 45 bodies were later recovered from the hospital.[84,85,86]
A network loop took down clinical applications at an academic medical centre for about four days, forcing a return to paper it had abandoned years earlier.[87,88,89,21]