Incident

Quest Diagnostics shuts down its Quanum LSM lab ordering and results system after unauthorized access; clients told to use paper requisitions

After a cyber intrusion, Quest Diagnostics shut down Quanum LSM, the web system some clients use to order lab tests and receive results, and paused two other systems as a precaution. Clients were told to use paper requisitions or another Quest platform. Quest says its ability to serve patients was not materially disrupted.

PathConnectivity & data → Human handoff

Sources checked when written 28 November 2026

TierClients ordering through the stopped system were advised to use paper requisitions or another Quest electronic platform, and Quest says patient service was not materially disrupted. The sources do not document care moving to paper, so no tier is assigned. How tiers are assigned.

What happened

On 21 October 2026 Quest Diagnostics learned of unauthorized access to its Quanum LSM (Lab Services Manager) system, according to the company's Form 8-K filing with the SEC. The filing describes LSM as a system that certain clients use to place test orders. BleepingComputer describes it as the online platform clients use to order tests, access results, track status and order supplies. Quest stopped access to LSM and, as a precaution, temporarily paused access to its Essential Insights and LabHQ systems. Quest says no data was accessed on those two systems (Fox Business, BleepingComputer). While LSM was down, clients that order through it were advised to use paper requisitions or Quest's Quanum eLabs platform (The Record, Fox Business, BleepingComputer). BleepingComputer reported that users of direct laboratory-information-system interfaces or EMRs were not affected. In the filing Quest said it believes an unauthorized party accessed certain patient records and that the full scope was still under investigation. It also said the incident "has not materially disrupted the Company's business operations or its ability to serve patients." Quest notified federal law enforcement and engaged external cybersecurity experts. Fox Business and The Record reported that Quest expected to restore the system as soon as Friday, 23 October. The sources opened for this entry do not confirm when access was restored.[1,2,3,4]

Documented harm

none documented

What it teaches

  • When a laboratory's web portal is a practice's only electronic route for ordering and results, a precautionary shutdown at the laboratory becomes an ordering outage at every client that uses it.
  • Sites connected through direct LIS or EHR interfaces were reported unaffected, so knowing which ordering path each site depends on is part of downtime planning.
  • Containment that pauses neighbouring systems as a precaution widens an outage, so downtime plans should cover shutdowns started by a vendor, not only local ones.
  • Keeping current paper requisitions on hand lets practices keep ordering tests when a supplier's system is taken offline without warning.

Sources

  1. Quest Diagnostics Incorporated Form 8-K (Item 8.01): unauthorized access to Quanum LSM system. Quest Diagnostics Incorporated / SEC EDGAR, 22 October 2026. Primary Official report · link checked 2026-11-02
  2. Quest Diagnostics confirms patient information accessed in cyberattack, systems temporarily shut down. Fox Business, 22 October 2026. Secondary Journalism · link checked 2026-11-28
  3. Quest Diagnostics takes lab ordering system offline after network intrusion. The Record from Recorded Future News, 23 October 2026. Secondary Journalism · link checked 2026-11-02
  4. Quest Diagnostics confirms data breach exposed patient records. BleepingComputer, 23 October 2026. Supporting Journalism · link checked 2026-11-02

Network failure at UZ Brussel takes down its shared patient record at partner hospitals; care moves to paper and ambulances are diverted for about a day

A network problem at UZ Brussel affected its IT infrastructure and telephony, according to the hospital. For about 24 hours, planned care was postponed, ambulances were diverted and staff worked on paper. Partner hospitals that use the same UZ Brussel-developed electronic patient record also lost online access to patient files.

PathConnectivity & data → Human handoff

Server outage at Monadnock Community Hospital: ambulance diversion, cancelled elective surgery, lab and radiology, and a week on downtime procedures

An outage that began on 9 November 2026 and that the hospital later called a server outage put Monadnock Community Hospital's emergency department on ambulance diversion. It also led the hospital to cancel elective surgery and outpatient laboratory and radiology appointments. The hospital said it was working under downtime procedures. As of 15 November its phones were restored, other systems were still down, and on 16 November it confirmed that a cyber incident caused the outage (DysruptionHub).

PathConnectivity & data → Human handoff

Synnovis pathology ransomware, South-East London

Ransomware hit Synnovis, the pathology provider for several south-east London NHS trusts and GP practices. Blood testing and matching collapsed, more than 11,000 appointments and procedures were postponed, O-type blood ran short nationally, and one death was later partly attributed to a delayed result.

PathConnectivity & data → Human handoff

Ascension ransomware and multi-week EHR downtime

A ransomware attack took Ascension's electronic records offline for about five weeks. Clinicians told KFF Health News of medication errors and delayed lab results, and one said he had no training for the attack; Ascension said its care teams were trained for such disruptions.

Change Healthcare ransomware and national claims/pharmacy clearinghouse outage

Attackers used stolen credentials on a Change Healthcare Citrix remote-access portal that had no multi-factor authentication, then deployed ransomware nine days later. Disconnecting the clearinghouse stalled pharmacy claims, medical claims and payments across the US.

PathConnectivity & data → Human handoff

Ransomware spillover to adjacent San Diego emergency departments

A month-long ransomware attack on a health system with about 25% of regional inpatient discharges was associated with higher census, ambulance arrivals, waits and stroke activations at two unaffected academic EDs nearby, according to a before-and-after cohort study.

PathConnectivity & data → Human handoff

All incidents · Connectivity & data · Cascades · Human handoff

Information only, not advice. FailSystems is an aggregation and synthesis of published sources. It is not consulting, engineering, legal, regulatory or medical advice, and using it creates no professional relationship. Health systems are complex and no approach fits every organisation: anything you adopt is your own decision, at your own risk, and should be checked against the current official sources and by qualified people who know your setting. Full disclaimer.