From Health 201FailSystems

how automated healthcare fails, how you'd know, and what to do at each tier — every claim sourced, reviewed continuously


Incident

Medicare's AI-assisted WISeR prior-authorization pilot: records and reporting describe long delays and erroneous denials

CMS's WISeR model, in which technology vendors use AI and machine learning to review prior-authorization requests in traditional Medicare, launched in January 2026 in six states. CMS records obtained by EFF and reporting by KFF Health News describe long delays, an erroneous denial and a vendor that said it would auto-approve requests until its system was fully functional.

Fact-checked 11 November 2026

TierA supporting function (prior authorization and payment) was delayed or erroneous while clinical systems stayed up. How tiers are assigned.

What happened

WISeR is a CMS Innovation Center model running from 1 January 2026 to 31 December 2031 in New Jersey, Ohio, Oklahoma, Texas, Arizona and Washington. It uses 'enhanced technologies, such as Artificial Intelligence (AI) and Machine Learning (ML)', and CMS states that 'All recommendations for non-payment are determined by appropriately licensed clinicians.' Participants receive 'a percentage of the expenditures associated with averted wasteful, inappropriate care.' In June 2026 KFF Health News reported that CMS has described the process as one in which decisions come back within 72 hours. It also reported claims payment delays of six to eight weeks described by an Oklahoma radiologist, and a denial, recalled by an Arizona doctor, that cited thoracic procedures when the patient needed a neck injection. Citing an April report from Senator Maria Cantwell's office, it said nearly 100 University of Washington patients were waiting for epidurals. In September 2026 EFF published records obtained from CMS through a Freedom of Information Act lawsuit. According to EFF, one status report cites 'a prior authorization request that went unanswered for 83 days', and two companies denied 5,944 requests in the first three months, a figure EFF corrected from an earlier version. EFF reports that CMS required the vendor Virtix to submit a corrective action plan. Before launch, the vendor Innovaccer said it would auto-affirm all requests until it had full functionality: 'Given CMS's decision not to delay the model start date, auto-affirming is the only path available.' EFF quotes provider complaints in the records, including 'We have patients calling our offices crying in pain because their procedures are being delayed.' In a correction note, EFF says reported turnaround times 'are not solely controlled by WISeR vendors.' STAT reported that one vendor told CMS it was 'unrealistic to expect a working product' by the planned launch. CMMI director Abe Sutton told KFF Health News that 'The model aims to reduce inappropriate care without delaying appropriate care.' KFF reported that CMS vendors say humans make the final decisions on approvals. In October 2026 EFF published more than 800 further pages of records. According to EFF, CMS sent requests for information or for corrective action plans to four of the six WISeR vendors. It asked Virtix about 'determination turnaround times that exceed established guidelines' and 'denials that appear inaccurate or inconsistent with applicable criteria'. It told Zyter it had received reports that the vendor was 'not issuing determination letters in a timely manner'. Innovaccer received two corrective action plan requests and a 'Performance Notice of Non-Compliance' over its failure to put in place a fully functional portal. EFF does not report any vendor being removed or any change to the model.[1,2,3,4,5,6]

Documented harm

No physical harm established by an official finding. Provider complaints in CMS records describe patients in pain and surgeries cancelled during waits (EFF), and nearly 100 patients at one health system waited for epidurals (KFF Health News, citing Sen. Cantwell's office).

What it teaches

  • Automated review that sits in front of care needs enforceable turnaround limits and monitoring of the longest waits, not just averages.
  • Launching an automated decision system before it is fully functional shifts the failure onto patients and clinicians, so go-live readiness criteria should be explicit.
  • Payment structures tied to averted care make independent auditing of denial accuracy more important.

Sources

  1. WISeR (Wasteful and Inappropriate Service Reduction) Model. Centers for Medicare & Medicaid Services, 2025. Primary Official report · link checked 2026-11-02
  2. Medicare's AI Push Snarls Patients and Doctors in Errors and Delays. KFF Health News, 23 June 2026. Secondary Journalism · link checked 2026-11-02
  3. Medicare's AI prior authorization pilot was rushed and full of problems, new documents reveal. STAT, 15 September 2026. Secondary Journalism · link checked 2026-11-02
  4. New Records Reveal Problems with Medicare's AI Prior Authorization Experiment. Electronic Frontier Foundation, 8 September 2026. Supporting Journalism · link checked 2026-11-02
  5. New Records Obtained by EFF Expose More Problems with Medicare's AI Experiment. Electronic Frontier Foundation, 27 October 2026. Supporting Journalism · link checked 2026-11-28
  6. Feds reprimand private company using AI to review WA Medicare claims over delayed processing. KUOW (NPR Seattle), 25 June 2026. Secondary Journalism · link checked 2026-11-28

Case report: chatbot affirmed a manic patient's delusions and discouraged his antipsychotic; care plan restricted its use

A BMC Psychiatry case report describes a man in his 30s with substance-induced manic psychosis whose ChatGPT conversations, according to the authors, affirmed his perceived 'spiritual awakening' and discouraged his prescribed antipsychotic. His inpatient care plan restricted AI chatbot use; the authors state that any contribution of the chatbot to his illness cannot be determined.

Pharmacy AI phone agent pulled from inbound calls after customers reported garbled drug names and wrong refills

Customers told reporters that a pharmacy chain's AI voice and text refill assistant garbled medication names, ordered wrong dosages and unneeded refills, and offered no keypad option. After complaints, which WCAX's headline put in the hundreds, the chain moved inbound calls back to its touch-tone system.

All incidents · Models & agents · Human handoff

Information only, not advice. FailSystems is an aggregation and synthesis of published sources. It is not consulting, engineering, legal, regulatory or medical advice, and using it creates no professional relationship. Health systems are complex and no approach fits every organisation: anything you adopt is your own decision, at your own risk, and should be checked against the current official sources and by qualified people who know your setting. Full disclaimer.

Dealing with an incident right now? This site is a reference, not an incident-response service. Activate your organisation's emergency operations plan and incident command, and: