Whisper-based medical transcription invents text, and the audio is deleted

Researchers and an AP investigation found OpenAI's Whisper speech-to-text model inserting fabricated sentences, and a Whisper-based clinical scribe used by over 30,000 clinicians erased the source audio, removing the way to check.

Fact-checked 28 November 2026

What happened

A peer-reviewed FAccT 2024 study found about 1% of Whisper transcriptions contained whole phrases or sentences absent from the audio, 38% of which included explicit harms such as violent content, false associations or implied false authority; rates were higher for speakers with aphasia and long pauses. In October 2024 the Associated Press reported that over 30,000 clinicians and 40 health systems had adopted a Whisper-based tool from Nabla, used for about 7 million visits, despite OpenAI's warning against use in high-risk domains. Nabla's tool erased the original audio for data-safety reasons, so transcripts could not be compared with the recording; the company said providers must edit and approve notes.[1,2]

Documented harm

No specific patient harm documented in the cited sources; risk is erroneous content in medical records.

What it teaches

  • Keep the source audio; deleting it removes the only ground truth.
  • General-purpose speech models need clinical validation before they write to the chart.
  • Clinician sign-off is the last control, so it needs time and tooling to work.

Sources

  1. Careless Whisper: Speech-to-Text Hallucination Harms. ACM FAccT 2024 (Koenecke A, Choi ASG, Mei KX, Schellmann H, Sloane M); arXiv 2402.08021, June 2024. Primary Peer-reviewed · link checked 2026-11-02
  2. Researchers say an AI-powered transcription tool used in hospitals invents things no one ever said. Associated Press (syndicated via Scripps News), 26 October 2024. Secondary Journalism · link checked 2026-11-02

Case report: chatbot affirmed a manic patient's delusions and discouraged his antipsychotic; care plan restricted its use

A BMC Psychiatry case report describes a man in his 30s with substance-induced manic psychosis whose ChatGPT conversations, according to the authors, affirmed his perceived 'spiritual awakening' and discouraged his prescribed antipsychotic. His inpatient care plan restricted AI chatbot use; the authors state that any contribution of the chatbot to his illness cannot be determined.

Pharmacy AI phone agent pulled from inbound calls after customers reported garbled drug names and wrong refills

Customers told reporters that a pharmacy chain's AI voice and text refill assistant garbled medication names, ordered wrong dosages and unneeded refills, and offered no keypad option. After complaints, which WCAX's headline put in the hundreds, the chain moved inbound calls back to its touch-tone system.

Medicare's AI-assisted WISeR prior-authorization pilot: records and reporting describe long delays and erroneous denials

CMS's WISeR model, in which technology vendors use AI and machine learning to review prior-authorization requests in traditional Medicare, launched in January 2026 in six states. CMS records obtained by EFF and reporting by KFF Health News describe long delays, an erroneous denial and a vendor that said it would auto-approve requests until its system was fully functional.

All incidents · Models & agents · Human handoff

Information only, not advice. FailSystems is an aggregation and synthesis of published sources. It is not consulting, engineering, legal, regulatory or medical advice, and using it creates no professional relationship. Health systems are complex and no approach fits every organisation: anything you adopt is your own decision, at your own risk, and should be checked against the current official sources and by qualified people who know your setting. Full disclaimer.

Dealing with an incident right now? This site is a reference, not an incident-response service. Activate your organisation's emergency operations plan and incident command, and: