Ransomware spillover to adjacent San Diego emergency departments

A month-long ransomware attack on a health system with about 25% of regional inpatient discharges was associated with higher census, ambulance arrivals, waits and stroke activations at two unaffected academic EDs nearby, according to a before-and-after cohort study.

PathConnectivity & data → Human handoff

Fact-checked 25 November 2026

TierThe study reports, citing local media, that the attacked system lost its electronic health records, imaging and telemedicine systems and reverted to paper records for about four weeks. The neighbouring EDs stayed at tier 0 under load. How tiers are assigned.

What happened

Dameff et al. (JAMA Network Open, 2023) compared two urban academic emergency departments that were not attacked before, during and after a ransomware attack on a neighbouring health system with about 25% of San Diego County's inpatient discharges. The attack-and-recovery phase ran from 1 to 28 May 2021. During that phase, compared with the 4 weeks before, the unaffected EDs saw a 15.1% rise in daily census, 35.2% more ambulance arrivals, a 127.8% rise in patients leaving without being seen, and a 47.6% rise in median waiting-room time. Confirmed strokes rose from 22 to 47, and county-wide EMS diversion hours also rose. The authors conclude that targeted hospital cyberattacks may be associated with disruptions of care at nontargeted hospitals in the same community and should be considered a regional disaster.[1,2]

Documented harm

Adverse outcomes at the attacked system are not documented in the source reviewed. At adjacent EDs, delays (longer waits and length of stay, more patients leaving without being seen) and higher stroke volumes were documented.

What it teaches

  • Neighbouring hospitals absorb the load of an attacked system without any warning.
  • Stroke and other time-critical pathways are where spillover shows first.
  • Regional plans need to treat one member's cyber outage as a regional surge event.
  • A multi-week tier 2 outage at one hospital raises the load on neighbouring hospitals, so exercise regionally.
  • Plan for weeks, not hours.
  • Time-critical pathways such as stroke need downtime versions at receiving hospitals too.

Sources

  1. Ransomware Attack Associated With Disruptions at Adjacent Emergency Departments in the US. JAMA Network Open (Dameff C, Tully J, Chan TC, et al.), 8 May 2023. Primary Peer-reviewed · link checked 2026-11-02
  2. Sentinel Event Alert Issue 67: Preserving patient safety after a cyberattack. The Joint Commission, 15 August 2023. Primary Guidance · link checked 2026-11-02

Network failure at UZ Brussel takes down its shared patient record at partner hospitals; care moves to paper and ambulances are diverted for about a day

A network problem at UZ Brussel affected its IT infrastructure and telephony, according to the hospital. For about 24 hours, planned care was postponed, ambulances were diverted and staff worked on paper. Partner hospitals that use the same UZ Brussel-developed electronic patient record also lost online access to patient files.

PathConnectivity & data → Human handoff

Server outage at Monadnock Community Hospital: ambulance diversion, cancelled elective surgery, lab and radiology, and a week on downtime procedures

An outage that began on 9 November 2026 and that the hospital later called a server outage put Monadnock Community Hospital's emergency department on ambulance diversion. It also led the hospital to cancel elective surgery and outpatient laboratory and radiology appointments. The hospital said it was working under downtime procedures. As of 15 November its phones were restored, other systems were still down, and on 16 November it confirmed that a cyber incident caused the outage (DysruptionHub).

PathConnectivity & data → Human handoff

Quest Diagnostics shuts down its Quanum LSM lab ordering and results system after unauthorized access; clients told to use paper requisitions

After a cyber intrusion, Quest Diagnostics shut down Quanum LSM, the web system some clients use to order lab tests and receive results, and paused two other systems as a precaution. Clients were told to use paper requisitions or another Quest platform. Quest says its ability to serve patients was not materially disrupted.

PathConnectivity & data → Human handoff

Synnovis pathology ransomware, South-East London

Ransomware hit Synnovis, the pathology provider for several south-east London NHS trusts and GP practices. Blood testing and matching collapsed, more than 11,000 appointments and procedures were postponed, O-type blood ran short nationally, and one death was later partly attributed to a delayed result.

PathConnectivity & data → Human handoff

Ascension ransomware and multi-week EHR downtime

A ransomware attack took Ascension's electronic records offline for about five weeks. Clinicians told KFF Health News of medication errors and delayed lab results, and one said he had no training for the attack; Ascension said its care teams were trained for such disruptions.

Change Healthcare ransomware and national claims/pharmacy clearinghouse outage

Attackers used stolen credentials on a Change Healthcare Citrix remote-access portal that had no multi-factor authentication, then deployed ransomware nine days later. Disconnecting the clearinghouse stalled pharmacy claims, medical claims and payments across the US.

PathConnectivity & data → Human handoff

All incidents · Connectivity & data · Human handoff · Cascades

Information only, not advice. FailSystems is an aggregation and synthesis of published sources. It is not consulting, engineering, legal, regulatory or medical advice, and using it creates no professional relationship. Health systems are complex and no approach fits every organisation: anything you adopt is your own decision, at your own risk, and should be checked against the current official sources and by qualified people who know your setting. Full disclaimer.