Incident

Princeton Community Hospital Petya ransomware

Ransomware made the EHR inaccessible; the hospital moved to paper within an hour and restored computers after 36 hours.

Fact-checked 23 November 2026

TierEHR and email down; paper and pen for medication and lab orders for about 36 hours. How tiers are assigned.

What happened

As recounted by the Joint Commission, staff arrived to find Petya ransomware notices. The EHR was inaccessible and email was down. Within an hour, the hospital activated its incident response plan and moved to paper and pen for medication and lab orders. It stayed open but diverted emergency cases. Surgeries and diagnostics continued, except for a few patients whose allergy information could not be accessed. IT had computers running again 36 hours after the attack using cloud backup and disaster-recovery software, but had to replace hard drives (TJC SEA 67, citing Healthcare IT News, Aug. 2017).[1,2,3]

Documented harm

none documented

What it teaches

  • A rehearsed plan got the hospital to paper within an hour.
  • Tested backups set how long you stay at tier 2.
  • Allergy information was the gap that stopped some procedures, so make sure it is in the downtime snapshot.

Sources

  1. Sentinel Event Alert Issue 67: Preserving patient safety after a cyberattack. The Joint Commission, 15 August 2023. Primary Guidance · link checked 2026-11-02
  2. Princeton hospital to replace 12-hundred computer hard drives after cyber attack. WV MetroNews (Carrie Hodousek), 30 June 2017. Secondary Journalism · link checked 2026-11-02
  3. Cyber attack prompts Princeton Community Hospital to rebuild network. Bluefield Daily Telegraph (Blake Stowers), 29 June 2017. Secondary Journalism · link checked 2026-11-02

IT outage takes down the whole IT system at Luxembourg's Centre Hospitalier du Nord; records go to paper and ambulances are redirected

On 23 November 2026 an IT outage affected the entire IT system of the Centre Hospitalier du Nord in Ettelbruck, according to the hospital. Inpatient records were made available on paper, outpatient appointments were cancelled and ambulances were directed to other hospitals until the system was restored shortly after 18:00. The hospital said the cause was purely technical and not a cyberattack.

Suspected ransomware attack on Guadeloupe's university hospital: records unreachable, staff on pen and paper, radiotherapy suspended

On the evening of Saturday 21 November 2026 a cyberattack disrupted IT and telephone systems at the University Hospital of Guadeloupe, which triggered its Plan Blanc emergency plan the next day and postponed non-urgent surgery, consultations and scheduled imaging through 27 November. France's cybersecurity agency ANSSI said the incident appeared to involve ransomware, and the Paris prosecutor opened a criminal investigation.

Network failure at UZ Brussel takes down its shared patient record at partner hospitals; care moves to paper and ambulances are diverted for about a day

A network problem at UZ Brussel affected its IT infrastructure and telephony, according to the hospital. For about 24 hours, planned care was postponed, ambulances were diverted and staff worked on paper. Partner hospitals that use the same UZ Brussel-developed electronic patient record also lost online access to patient files.

PathConnectivity & data → Human handoff

Server outage at Monadnock Community Hospital: ambulance diversion, cancelled elective surgery, lab and radiology, and a week on downtime procedures

An outage that began on 9 November 2026 and that the hospital later called a server outage put Monadnock Community Hospital's emergency department on ambulance diversion. It also led the hospital to cancel elective surgery and outpatient laboratory and radiology appointments. The hospital said it was working under downtime procedures. As of 15 November its phones were restored, other systems were still down, and on 16 November it confirmed that a cyber incident caused the outage (DysruptionHub).

PathConnectivity & data → Human handoff

Quest Diagnostics shuts down its Quanum LSM lab ordering and results system after unauthorized access; clients told to use paper requisitions

After a cyber intrusion, Quest Diagnostics shut down Quanum LSM, the web system some clients use to order lab tests and receive results, and paused two other systems as a precaution. Clients were told to use paper requisitions or another Quest platform. Quest says its ability to serve patients was not materially disrupted.

PathConnectivity & data → Human handoff

Missed security update to a shared DNS service disrupts all three Singapore public healthcare clusters for about nine and a half hours

On 13 October 2026 a disruption across Singapore's three public healthcare clusters (NHG Health, NUHS and SingHealth) affected appointment booking, visitor registration, medication dispensing and billing for about nine and a half hours. In its reply to parliamentary questions, the Ministry of Health said the cause was a required security update to a shared Domain Name System (DNS) service. Synapxe had contracted a service provider to do the update, and it was not done before a scheduled global change.

PathConnectivity & data → Human handoff

All incidents · Connectivity & data · Human handoff

Information only, not advice. FailSystems is an aggregation and synthesis of published sources. It is not consulting, engineering, legal, regulatory or medical advice, and using it creates no professional relationship. Health systems are complex and no approach fits every organisation: anything you adopt is your own decision, at your own risk, and should be checked against the current official sources and by qualified people who know your setting. Full disclaimer.

Dealing with an incident right now? This site is a reference, not an incident-response service. Activate your organisation's emergency operations plan and incident command, and: