Incident

VA Oracle Cerner EHR 'unknown queue' silently dropped clinical orders

After go-live, the new EHR routed more than 11,000 clinical orders to a hidden queue instead of the intended service, without telling the ordering clinician; VHA identified 149 adverse events.

Sources checked when written 26 September 2026

TierThe automation stayed up and kept producing output that was wrong or went unchecked; there was no outage to fall back from. How tiers are assigned.

What happened

The new EHR let providers pick service locations that the system could not match; unmatched orders went to an 'unknown queue' rather than to specialty care, lab or imaging, and the provider received no alert. From go-live in October 2020 to June 2021 more than 11,000 orders were not delivered. The first trouble ticket about lost orders was placed on 28 October 2020, four days after go-live; the OIG found no evidence that the vendor gave VA actionable information about the queue beforehand. VHA's clinical review of 1,286 event assessments classified 149 adverse events (2 major, 52 moderate, 95 minor). Mitigation relied on staff manually monitoring and re-entering queued orders; 206 orders were still in the queue across VHA sites on 16 May 2022.[1]

Documented harm

149 adverse events classified by VHA: 2 major harm, 52 moderate, 95 minor.

What it teaches

  • The dangerous failure is the one that looks like success: every order appeared placed.
  • Every interface and routing layer needs a dead-letter queue that someone owns and watches daily.
  • Ask vendors to disclose every place data can be parked or dropped before go-live.

Sources

  1. The New Electronic Health Record's Unknown Queue Caused Multiple Events of Patient Harm (Report 22-01137-204). VA Office of Inspector General, 14 July 2022. Primary Official report · link checked 2026-11-02

IT outage takes down the whole IT system at Luxembourg's Centre Hospitalier du Nord; records go to paper and ambulances are redirected

On 23 November 2026 an IT outage affected the entire IT system of the Centre Hospitalier du Nord in Ettelbruck, according to the hospital. Inpatient records were made available on paper, outpatient appointments were cancelled and ambulances were directed to other hospitals until the system was restored shortly after 18:00. The hospital said the cause was purely technical and not a cyberattack.

Suspected ransomware attack on Guadeloupe's university hospital: records unreachable, staff on pen and paper, radiotherapy suspended

On the evening of Saturday 21 November 2026 a cyberattack disrupted IT and telephone systems at the University Hospital of Guadeloupe, which triggered its Plan Blanc emergency plan the next day and postponed non-urgent surgery, consultations and scheduled imaging through 27 November. France's cybersecurity agency ANSSI said the incident appeared to involve ransomware, and the Paris prosecutor opened a criminal investigation.

Network failure at UZ Brussel takes down its shared patient record at partner hospitals; care moves to paper and ambulances are diverted for about a day

A network problem at UZ Brussel affected its IT infrastructure and telephony, according to the hospital. For about 24 hours, planned care was postponed, ambulances were diverted and staff worked on paper. Partner hospitals that use the same UZ Brussel-developed electronic patient record also lost online access to patient files.

PathConnectivity & data → Human handoff

Server outage at Monadnock Community Hospital: ambulance diversion, cancelled elective surgery, lab and radiology, and a week on downtime procedures

An outage that began on 9 November 2026 and that the hospital later called a server outage put Monadnock Community Hospital's emergency department on ambulance diversion. It also led the hospital to cancel elective surgery and outpatient laboratory and radiology appointments. The hospital said it was working under downtime procedures. As of 15 November its phones were restored, other systems were still down, and on 16 November it confirmed that a cyber incident caused the outage (DysruptionHub).

PathConnectivity & data → Human handoff

Quest Diagnostics shuts down its Quanum LSM lab ordering and results system after unauthorized access; clients told to use paper requisitions

After a cyber intrusion, Quest Diagnostics shut down Quanum LSM, the web system some clients use to order lab tests and receive results, and paused two other systems as a precaution. Clients were told to use paper requisitions or another Quest platform. Quest says its ability to serve patients was not materially disrupted.

PathConnectivity & data → Human handoff

Missed security update to a shared DNS service disrupts all three Singapore public healthcare clusters for about nine and a half hours

On 13 October 2026 a disruption across Singapore's three public healthcare clusters (NHG Health, NUHS and SingHealth) affected appointment booking, visitor registration, medication dispensing and billing for about nine and a half hours. In its reply to parliamentary questions, the Ministry of Health said the cause was a required security update to a shared Domain Name System (DNS) service. Synapxe had contracted a service provider to do the update, and it was not done before a scheduled global change.

PathConnectivity & data → Human handoff

All incidents · Connectivity & data · Human handoff

Information only, not advice. FailSystems is an aggregation and synthesis of published sources. It is not consulting, engineering, legal, regulatory or medical advice, and using it creates no professional relationship. Health systems are complex and no approach fits every organisation: anything you adopt is your own decision, at your own risk, and should be checked against the current official sources and by qualified people who know your setting. Full disclaimer.

Dealing with an incident right now? This site is a reference, not an incident-response service. Activate your organisation's emergency operations plan and incident command, and: