Wrong AI suggestions pull radiologists' mammogram ratings off

In a controlled experiment, 27 radiologists' accuracy on mammograms fell sharply when a purported AI suggested an incorrect BI-RADS category.

Fact-checked 11 November 2026

What happened

Dratsch and colleagues had 27 radiologists read 50 mammograms with a purported AI suggesting a BI-RADS category; in 12 of 40 test cases the suggestion was deliberately wrong. Correct ratings fell from 79.7% to 19.8% for inexperienced readers, 81.3% to 24.8% for moderately experienced readers, and 82.3% to 45.5% for very experienced readers when the suggestion was incorrect. Inexperienced readers were most likely to follow incorrect higher-category suggestions. This is an experiment, not a clinical event, and is listed as the clearest measurement of automation bias in a clinical task.[1]

Documented harm

None (experimental setting).

What it teaches

  • Expertise reduces automation bias but does not remove it.
  • An AI that is usually right trains readers to follow it when it is wrong.

Sources

  1. Automation Bias in Mammography: The Impact of Artificial Intelligence BI-RADS Suggestions on Reader Performance. Radiology 307(4):e222176 (RSNA), 2 May 2023. Primary Peer-reviewed · link checked 2026-11-02

Pharmacists accept most wrong LLM recommendations when verifying medication orders

In a randomized simulation trial at UCSF, 77 pharmacists and pharmacy trainees verified medication orders with and without GPT-4o recommendations. Assistance raised overall accuracy, but participants accepted 73.9% of incorrect AI recommendations, and their accuracy fell to 26.1% when the AI was wrong.

Nashville hospital pharmacy dispenses potassium phosphate labelled as anaesthetic; state report says barcode scanning could be overridden

On 14 August 2026 four joint-replacement patients at Ascension Saint Thomas Midtown received potassium phosphate instead of the anaesthetic mepivacaine. FOX 17 News, in a report published on NewsChannel 9's website, said a state survey report found that the pharmacy system let technicians override barcode scanning and that the pharmacist's final check also missed the wrong drug. In November 2026 one patient sued the hospital.

ICU patient dies after alarms go unanswered for an hour

A 60-year-old ICU patient's monitor alarmed for rising heart rate and falling oxygen saturation; staff responded only after about an hour, when he had stopped breathing.

All incidents · Human handoff · Models & agents

Information only, not advice. FailSystems is an aggregation and synthesis of published sources. It is not consulting, engineering, legal, regulatory or medical advice, and using it creates no professional relationship. Health systems are complex and no approach fits every organisation: anything you adopt is your own decision, at your own risk, and should be checked against the current official sources and by qualified people who know your setting. Full disclaimer.

Dealing with an incident right now? This site is a reference, not an incident-response service. Activate your organisation's emergency operations plan and incident command, and: