Incident

Pharmacists accept most wrong LLM recommendations when verifying medication orders

In a randomized simulation trial at UCSF, 77 pharmacists and pharmacy trainees verified medication orders with and without GPT-4o recommendations. Assistance raised overall accuracy, but participants accepted 73.9% of incorrect AI recommendations, and their accuracy fell to 26.1% when the AI was wrong.

Sources checked when written 28 November 2026

TierSimulation study; no tier applies. How tiers are assigned.

What happened

Surdilla and colleagues, writing in the American Journal of Health-System Pharmacy, randomly assigned each of 10 clinical scenario questions to an unassisted arm or an AI-assisted arm. In the assisted arm, OpenAI's GPT-4o gave a binary 'verify' or 'not verify' recommendation with an explanation. Participants were 29 students, 14 PGY1 residents, 11 PGY2 residents and 23 pharmacists. AI assistance was associated with higher overall accuracy (adjusted odds ratio 1.58; 95% CI 1.16-2.15), with the greatest benefit among students and the least among PGY2 residents. Performance depended on whether the AI was right. With correct recommendations, user accuracy was 80.2%; with incorrect ones, it fell to 26.1%. Participants accepted 80.2% of correct recommendations and 73.9% of incorrect ones. When users disagreed with the AI, their accuracy was 21.7%, which the authors describe as participants being rarely successful when attempting to override the model. The authors conclude that AI should augment, not replace, pharmacist judgment, and that safe integration requires pharmacist-guided validation of model output and training focused on trust. These findings match the pattern described in an earlier systematic review of automation bias in clinical decision support, which found that over-reliance is shaped by trust, experience, workload and time pressure.[1,2]

Documented harm

none documented (simulation)

What it teaches

  • An assistant that raises average accuracy can still make reviewers much worse on the cases where it is wrong, so evaluations should report accuracy separately for correct and incorrect AI output.
  • Less experienced staff may gain most from assistance and also be most exposed to its errors, which matters where trainees do first-line verification.
  • Training on when to distrust a recommendation is part of deploying the tool, not an optional extra.

Sources

  1. Impact of AI assistance on pharmacist and pharmacy trainee accuracy and automation bias during medication order verification: A randomized simulation trial. American Journal of Health-System Pharmacy, 25 September 2026. Primary Peer-reviewed · link checked 2026-11-02
  2. Automation bias: a systematic review of frequency, effect mediators, and mitigators. Journal of the American Medical Informatics Association 19(1):121-127, January 2012. Primary Peer-reviewed · link checked 2026-11-02

Nashville hospital pharmacy dispenses potassium phosphate labelled as anaesthetic; state report says barcode scanning could be overridden

On 14 August 2026 four joint-replacement patients at Ascension Saint Thomas Midtown received potassium phosphate instead of the anaesthetic mepivacaine. FOX 17 News, in a report published on NewsChannel 9's website, said a state survey report found that the pharmacy system let technicians override barcode scanning and that the pharmacist's final check also missed the wrong drug. In November 2026 one patient sued the hospital.

ICU patient dies after alarms go unanswered for an hour

A 60-year-old ICU patient's monitor alarmed for rising heart rate and falling oxygen saturation; staff responded only after about an hour, when he had stopped breathing.

All incidents · Human handoff · Models & agents

Information only, not advice. FailSystems is an aggregation and synthesis of published sources. It is not consulting, engineering, legal, regulatory or medical advice, and using it creates no professional relationship. Health systems are complex and no approach fits every organisation: anything you adopt is your own decision, at your own risk, and should be checked against the current official sources and by qualified people who know your setting. Full disclaimer.

Dealing with an incident right now? This site is a reference, not an incident-response service. Activate your organisation's emergency operations plan and incident command, and: